Choosing an Aqueous Pigment Ink for Epson I3200 and S3200 Printheads

A formulator moving an aqueous pigment ink from an I3200 to an S3200 needs the full model code before adjusting the vehicle. Even within the S3200 family, Epson gives two different viscosity ranges for aqueous ink. The fluid path also changes what you need to measure during a production trial.

Which Epson model is installed?

Check the code on the printer’s parts list or ask the integrator. Epson designates the four variants below for aqueous fluids. Its I3200(4)-U1 and -E1, I3200(8)-S1HD, and S3200-U1-2 and -U3-2 have different ink-type designations. A matching nozzle count does not identify the fluid family.

Epson’s reference viscosity ranges for the finished aqueous ink
Head modelViscosity (mPa·s)Ink recirculation inside the headOEM sheet
I3200(4)-A12.2–4.5None listedI3200(4) PDF
I3200(8)-A1HD2.2–3.8None listedI3200(8) PDF
S3200-A13.2–4.4Common channelS3200 PDF
S3200-A35.0–7.0Common channel

Epson marks these viscosity figures as reference values. The sheets list no internal heater for the four aqueous heads and give no measurement temperature beside the viscosity figures. Ask the machine builder for the intended ink temperature, control tolerance and approved fluid test method. An external ink-conditioning system may affect the temperature at the head.

Would a 4.0 mPa·s ink suit all four?

Suppose the finished ink measures 4.0 mPa·s under conditions comparable to the manufacturer’s reference. It falls inside the listed ranges for I3200(4)-A1 and S3200-A1, above the range for I3200(8)-A1HD and below the range for S3200-A3. Passing that comparison gives the lab a reason to run a drop test. It leaves open how the ink refills the chamber, breaks into drops and restarts after a pause.

Begin with the approved reference ink. Equilibrate it and the candidate at the same temperature and measure both by the same method. If the candidate needs a vehicle adjustment, repeat the pigment stability and filtration checks after mixing. Changing the humectant balance can also change nozzle-face drying and the time needed for the print to dry.

How should the idle and circulation trials differ?

I3200. An external tank stirrer or supply loop can keep ink moving upstream while fluid rests inside the head. Use the normal capping and maintenance settings, hold a defined idle period, and save the first nozzle check on restart. Record missing or deflected jets and the number of standard cleaning cycles needed for recovery. Repeat with the reference ink after the same pause.

S3200. Epson identifies circulation through a common channel. Record the printer’s normal circulation and idle settings, then sample the supply and return at the same points before and after the run. Compare fluid temperature, particle distribution and filter pressure change. Use nozzle checks to establish what happens at the nozzles. Return-line flow alone gives no measurement of individual nozzle recovery.

For either family, keep the reference waveform, firing conditions and print mode fixed for the first comparison. Where a drop watcher is available, record drop velocity, trajectory and satellites. Set acceptance limits with the integrator using the qualified ink and the intended duty cycle.

Which AIC data belong in the trial record?

For a cyan trial, AIC-Cyan 6900 is a PB15:3 concentrate with nominal 15 wt% pigment. Its published sample report gives D50 of 141 nm and D90 of 197 nm. Record the lot, the pigment concentration in the finished ink and the filter medium used. Repeat the size and throughput measurements after mixing with your binder and vehicle. Epson’s sheets above provide no pigment D90 limit that would qualify this grade for a printer. Cyan 6900 particle-size report · Reading percentiles for a printhead trial.

Include the complete head code, ink temperature, current reference ink, intended substrate and normal idle interval when requesting a sample. Those details make it possible to select a colourant and define a useful comparison before committing ink to the machine. Request a Cyan 6900 evaluation sample.