Self-Dispersed vs Polymer-Dispersed Pigments for Inkjet

Two PB15:3 cyan dispersions can arrive with similar median particle sizes and behave quite differently once the binder is added. The choice turns on what keeps their particles apart in your ink. A matched trial using zeta potential, conductivity and filter performance can show where a candidate loses stability.

Which dispersion should enter the trial?

For a self-dispersed grade, ask which groups are attached to the pigment and what pH range the supplier recommends. For a polymer-dispersed grade, ask how much pigment and how much polymer the concentrate contains. The same total solids can correspond to different amounts of pigment and different amounts of polymer carried into the finished ink.

Take cyan as a worked example. At a nominal 15 wt% pigment, 20.0 g of AIC-Cyan 6900 supplies 3.0 g of PB15:3 in a 100 g trial ink. For a second concentrate containing 12 wt% actual pigment, the corresponding addition would be 25.0 g. Adjust the vehicle balance to keep the trial at 100 g. The second concentration is an arithmetic example. Obtain the actual pigment fraction for each lot before weighing it. AIC-Cyan 6900 grade data.

What keeps the particles apart?

In AIC's carboxylic self-dispersed route, the pigment carries hydrophilic surface groups. Ionised carboxyl groups contribute to electrostatic repulsion. Lowering pH can reduce that ionisation. Dissolved salts can shorten the distance over which charged particles repel each other. Either change can allow particles to approach closely enough to form aggregates.

In an adsorbed-polymer dispersion, segments of a dispersant anchor to the pigment. Other segments extend into the liquid. Well-solvated chains resist being crowded together as two particles approach. An ionic polymer can provide both this steric barrier and electrostatic repulsion. A change in solvent mix or binder can alter the effectiveness of the adsorbed layer. A modest zeta-potential magnitude can therefore coexist with good storage stability. BYK’s account of steric stabilisation.

Ask the supplier to distinguish an adsorbed dispersant from a deliberately formed polymer shell. Encapsulation describes a pigment–polymer structure. The word “polymer-dispersed” alone tells you too little to infer a continuous shell or textile fixation. Pigment encapsulation and textile fixation.

A published PB15:3 experiment shows why a fresh particle-size reading can miss a formulation problem. Atsushi Nishida varied the synergist paired with a polymeric dispersant. Two samples began at nearly the same mean size, 149.1 and 150.3 nm. After 14 days at 40 °C the reported means were 149.2 and 180.1 nm respectively. The second sample’s viscosity also rose from 9.4 to 12.9 mPa·s. These are mean diameters from two experimental dispersions. An AIC grade or a D95 acceptance limit would need its own measurements. Nishida, experimental conditions and Table 3.

What do zeta potential and conductivity actually measure?

Zeta potential (mV) describes the electrical potential at the slipping plane, where liquid starts to move relative to the particle. In electrophoretic light scattering the instrument measures particle mobility in an electric field. It converts mobility to zeta potential using a model and liquid properties such as viscosity and permittivity. Record the model and use properties appropriate to the water–humectant mixture. Keep the sign in the report. ISO 13099-2:2025, optical mobility measurements.

Concentrated or strongly absorbing ink may need dilution for the instrument. Use a clear aliquot of the sample’s continuous phase where practical, or prepare a diluent that reproduces its pH, ions and free additives. Record the dilution ratio and temperature. Diluting in pure water may change the very charge or adsorption equilibrium you intend to investigate. Malvern Panalytical’s guidance on sample dilution.

Conductivity (µS/cm or mS/cm) measures how readily the liquid carries electrical current. It depends on the mobile ions, their concentrations and the temperature. Ionic strength also depends on ion charge. A sodium salt and a calcium salt can give similar conductivity readings while interacting differently with a carboxylated pigment. Record which salts were present and measure the undiluted ink as well as any diluted sample used for electrophoresis. A reading of 1.0 mS/cm equals 1,000 µS/cm. USGS guidance on conductivity units, calibration and temperature.

How do you set acceptance criteria for an ink?

Use a qualified reference ink, a pigment-free vehicle blank and the two candidate inks. Prepare the candidates at equal pigment loading with the same binder, humectants and process water. Fix the addition order, temperature and mixing time. Retain samples before and after binder addition. If the binder is a latex, its own particles can contribute to the size and mobility signals in the finished ink. Measure the blank before attributing a new population to pigment.

What to record for each candidate and the qualified reference
ParameterConditions to recordDecision in the trial
Zeta potential and pHMobility, sign and mV value, measured pH, cell temperature, diluent, conversion model and repeatability.Investigate a reproducible shift that accompanies coarse-particle growth. A single absolute mV threshold cannot rank a steric barrier.
ConductivityCalibrated cell, units, sample temperature and any compensation setting. Measure water, blank vehicle and ink separately.Compare lots at the same temperature and formulation. If conductivity rises, test the suspect water or additive separately before changing pigment grade.
Particle size after ageingD50 and measured D95 in nm, distribution basis, preparation, instrument, storage temperature and duration. Measure fresh and aged samples by the same method.Set a maximum tail size or allowable drift from an approved ink with repeat measurements. Request a measured D95 if the supplier reports only D90 and D97.
Filtration and idle recoveryFilter material, rating and area, volume passed at fixed pressure, plus nozzle checks after a defined idle time and cleaning sequence.Advance a candidate when filter throughput and nozzle recovery meet the limits established on your line, including after storage.

If both inks filter when fresh but one loses throughput after adding binder, repeat the addition with the blank and compare the retained material. If the same ink tolerates the binder but develops a coarse tail with a new process-water lot, test the water change on its own. These two observations point to different corrective actions. Establish the allowable ranges with repeat preparations of the reference and confirm the selected ink on the intended head.

Data for the next trial

For a cyan screen, start with the model’s reported pigment loading and fluid properties. Then work with the head supplier to agree the finished-ink conditions. Compare AIC concentrate data sheets · Read particle-size reports and check printhead fit.